    GE Voluson i Portable Ultrasound

    The GE Voluson i ultrasound was the first 4D ultrasound, and many sonographers, physicians, radiologists, and other users still consider the Voluson i model to be one of the best on the market today.

    From its excellent frame rates to surprisingly good image quality and transducer penetration, the compact GE Voluson i ultrasound provides a remarkable combination of high performance and reliability. The GE Voluson i is specifically engineered, and packed with advanced features, to be your first-choice ultrasound when covering virtually all applications from adolescence, preconception, and pregnancy to gynecology, breast, and post menopausal care.

    Description

    GE Voluson i Portable Ultrasound Machine For Sale

    The GE Voluson i portable ultrasound machine, is the most advanced portable 4D ultrasound machine for women’s health in the world today. It offers the widest range of 4D transducers, and GE’s class-leading 4D imaging as well as proprietary GE efficiency technologies that speed up workflow. The Voluson i ultrasound machine is focused on Women’s Health but it can also support general imaging and vascular applications. Those familiar with the famous Voluson 730 will find image quality and speed similar in the Voluson i even though it is only the size of a laptop. Key technologies from the more expensive Voluson E8 like SonoNT, STIC, SonoVCAD heart, SonoAVC follical, and SonoVCAD labor are all available either standard or as options on the Voluson i. KPI, the largest distributor of diagnostic ultrasound equipment in the world offers the GE Voluson i for sale worldwide. The Voluson i price ranges from $20,000 to $50,000 dollars depending upon the revision (BT), condition, years of use, and the probes included. Click on the tabs below to see the Voluson i brochure, probes, and more.

    CLICK HERE TO REQUEST A PRICE QUOTE

    Application training for the GE Voluson i

    KPI’s on-staff sonographer can provide onsite applications training or remote training via video conference for the Voluson i at a set price plus travel costs. A pre-recorded video training course is included in the sale, lease or rental of the Voluson i from KPI ultrasound.

    Voluson i Service options

    Free technical support is available from KPI during installation and over the course of the standard limited warranty. Technical support is available after the warranty period at an hourly cost per issue.

    GE Voluson i Maintenance

    KPI recommends the use of a surge protector along with a dedicated power outlet. Probes should be disinfected after every use with a disinfectant wipe proven not to damage the lens (KPI recommends SonoWipes for this.) KPI recommends one PM (preventative maintenance) every year.

    GE Voluson i Dimensions & Weight

    Height: 70 mm (2.5 in)
    Width: 391 mm (14.2 in)
    Depth: 378 mm (12.4 in)
    Weight: (no peripherals) 5.7 kg (12.3 lbs.) (includes battery), 5 kg (11 lbs.) (without battery), approx. 38 lbs. with packaging

    Voluson i Specifications

    Digital Beam former
    184.889 MLA2
    Displayed Imaging Depth: 0 – 30 cm
    Minimum Depth of Field: 0 – 1 cm (Zoom, probe dependent)
    Maximum Depth of Field: 0 – 30 cm (probe dependent)
    Up to 239 dB Dynamic Range

    GE Voluson i Electrical

    Voltage: 100 – 250 V
    Frequency: 47/63 Hz

    Revisions

    GE Voluson i Revisions: BT06 to BT07

    GE first launched the Voluson i in 2006 at the same time as the Voluson E8. That first version was designated as BT06. “BT” is an abbreviation of “Break Through” and the number designates the year in which this version was launched. So the Voluson i BT06 was launched in 2006 and was in production till the next version in 2007, the v Voluson i BT07. The BT07 revision provided minor bug fixes to the software and support for two new transducers; the RAB4-8-RS 4D high frequency convex and the RNA5-9-RS 4D microconvex.

    GE Voluson i Revisions: BT09 to BT14

    The Voluson i BT09 revision was a huge update and added the following features and options: VCI, XTD View, STIC, SonoAVC, SonoVCAD Heart, SonoVCAD Labor, HD Flow, and HD-Zoom. In addition to this the GE Voluson-I BT09 also added support for five new transducers: the RIC5-9W-RS 4D intracavitary, the 9L-RS linear, the IC5-9W-RS intracavitary, the AB2-7-RS convex, and the SP10-16-RS high frequency linear. The next revision was BT11 that added the popular SonoNT option to automate the common Nuchal Translucency scan. The current revision in production is the Voluson-i BT14 that adds Volume CINE and support for the RAB2-6-RS 4D convex and 8C-RS microconvex probes. KPI recommends buying the Voluson i BT09 and newer.

    All revisions of the GE Voluson i

    GE Voluson i (BT06)
    GE Voluson i (BT07)
    GE Voluson i (BT09)
    GE Voluson i (BT11)
    GE Voluson i (BT14)

    Popular configurations of the Voluson i in 2016

    GE Voluson i BT11 with 2 transducers

    RAB4-8-RS 4D Convex

    E8C-RS 2D Endovaginal

    GE Voluson i BT14 with 3 transducers

    RAB4-8-RS 4D Convex

    4C-RS 2D Convex

    E8C-RS 2D Endovaginal

    Probes

    All GE Voluson i probes / transducers
    4D Convex RAB2-5-RS [ 1 – 4 MHz ] 192 elements, 46mm, max depth 30cm
    4D Convex RAB2-6-RS [ 2 – 6 MHz ] 192 elements, 46mm, max depth 26cm
    4D Convex RAB4-8-RS [ 2 – 8 MHz ] 192 elements, 46mm, max depth 26cm

    4D Microconvex RNA5-9-RS [ 3 – 9 MHz ] 192 elements, 15.4mm, max depth 18cm

    4D Endocavitary RIC5-9-RS [ 4 – 9 MHz ] 192 elements, 11.6mm radius, max depth 16cm
    4D Endocavitary RIC5-9W-RS [ 4 – 9 MHz ] 192 elements, 11.3mm radius, max depth 16cm

    4D Linear RSP6-16-RS [ 6 – 18 MHz ] 192 elements, 80.7mm volume sweep radius

    Convex 4C-RS [ 2 – 5 MHz ] 128 elements, 60.5mm, max depth 30cm
    Convex AB2-7-RS [ 2 – 8 MHz ] 192 elements, 41.2mm, max depth 28cm
    Microconvex 8C-RS [ 4 – 11 MHz ] 128 elements, 26mm

    Endocavitary E8C-RS [ 4 – 10 MHz ] 128 elements, 11.4m, max depth 16cm
    Endocavitary IC5-9W-RS [ 3 – 10 MHz ] 192 elements, 11mm radius, max depth 16cm

    Linear 12L-RS [ 4 – 12 MHz ] 192 elements, 37mm FOV, max depth 8cm
    Linear 9L-RS [ 3 – 8 MHz ] 192 elements, 43mm FOV, max depth 14cm
    Linear SP10-16-RS [ 7 – 18 MHz ] 192 elements, 33.7mm FOV, max depth 6cm

    Advanced Voluson i probes
    The GE Voluson i supports thirteen transducers. As the premier 4D portable the Voluson-i has 6 compatible volume probes including the rare [ 6 – 18 MHz ] RSP6-16-RS high frequency 4D linear transducer excellent for small parts, peripherals, pediatrics and vascular and the RNA5-9-RS 4D microconvex another rare option on any ultrasound machine, especially a portable.

    Popular GE Voluson i probes
    The RAB4-8-RS is the most popular 4D convex probe with a wide range. The RIC5-9W-RS is the most popular endocavitary probe for the Voluson-i. The 4C-RS is the most popular and inexpensive 2D convex and both the 12L-RS is the most commonly purchased linear probe for the Voluson-i.

    Voluson i comparison with other GE ultrasound machines

    The Voluson-i was launched in 2006 as the portable counterpart to the Voluson E8 and has many of the same features. In 2009, the slightly less expensive Voluson-e was launched with fewer features and transducers. The GE Logiq-e is similar in power and price to the Voluson-e but offers access to cardiac transducers and lacks the 4D probes. The Voluson-i has similar speed and image quality to the Voluson S6 and slightly superior to the Voluson 730.

    Voluson-i vs Voluson-e

    The GE Voluson-e looks identical to the more expensive Voluson-i, but the differences are in the software. The Voluson-e was launched in 2009 as a BT09 and lacks the following features: TUI (Tomographic Ultrasound Imaging) a multi slice imaging feature that allows doctors to manipulate and use ultrasound imagery as they would CT or MRI imagery, VCI (Volume Contrast Imaging), 4D biopsy, and STIC. In addition, the Voluson-e does NOT support the following transducers from the Voluson-i: 9L-RS linear, RNA5-9RS 4D microconvex, and SP10-16-RS high frequency linear. If these functions are transducers are not of use in your practice then the Voluson-e offers you a slightly more affordable option than the Voluson-i.

    Features

    GE Voluson i Standard Features

    These are features that are standard on the GE Voluson-i revision BT11.

    15” TFT LCD Screen
    1 Active Probe Port
    3D/4D Mode
    Innovative user interface with onscreen menus
    HD-Flow
    AO (Automatic Tissue Optimization)
    OTI (Optimized Tissue Imaging)
    Coded Harmonic Imaging
    SRI II (Speckle Reduction Imaging II)
    CrossXBeam CRI
    Static 3D Mode:
    B-Mode only
    B Power Doppler Mode
    B CFM Doppler Mode
    B HD-Flow Mode
    B CRI
    B SRI
    B SRI CFM
    B SRI HD-Flow
    FFC (Focus Frequency Composite)
    Read Zoom
    HD Zoom (High Resolution Zoom)
    Pan Zoom
    Beam Steering
    Virtual Convex
    Beta View
    Trapezoid Mode
    Multi Format (Dual/Quad screen)
    SonoNT (regional availability limitation)
    SonoRenderStart
    Patient information database
    SonoView II: On-board image/data storage software
    CINE mode with CINE Memory: up to 140 MB (3000 2D images)
    Dual/Quad Image
    Review Loop, 4 Review speeds
    Real-Time automatic Doppler Calculations
    Standby Mode
    OB, GYN, Vascular, Neuro, Cardio, Abdominal, Small Parts, Urology, Pediatric Measurements & Calculations
    Integrated HD
    Proprietary Battery Slot
    Handle

    GE Voluson i technology definitions

    SRI II: Speckle Reduction Imaging allows the Voluson-i to use a nonlinear diffusion filtering technique that improves image quality in real time by reducing speckles.

    CrossXBeam CRI: This is another technology borrowed from the E8. It is compound resolution imaging used to improve border and image clarity the Voluson-i.

    FFC: Focus and Frequency Composite is a technology on the GE Voluson i that utilizes two different transmission frequencies and two different focal ranges in the 2D image. This function combines a low frequency to increase the penetration and higher frequency to keep a high resolution. It reduces speckle and artifacts in the 2D image to facilitate the examination of difficult-to-scan patients.

    Beta View: On the Voluson-i this feature allows the adjustment of the Volume O-Axis position of 3D probes in 2D mode. The green line in the displayed symbol indicates the position of the acoustic block. and – define the corresponding sweep directions on the Touch screen.

    SonoNT: A Voluson i technology that allows for semi-automatic Nuchal Translucency measurements.

    SonoRender Start: A feature on the GE Voluson i that speeds up the acquisition of the fetal face in 4D.

    Accessories

    GE Voluson i Accessories

    Sony UPD-897MD Digital Black & white thermal printer
    Sony UPD-898MD Digital Black & white thermal printer
    Sony UPX-898MD Digital Black & white thermal printer
    Sony UPD-25MD Digital Color thermal printer
    Mitsubishi P95DW Digital Black & white thermal printer
    Mitsubishi CP30DW Digital Color thermal printer
    Sony DVO-1000 DVD Recorder
    CIVCO disposable biopsy guides (for Convex, Linear and Endo-cavity transducers)

    Voluson i Supplies

    Aquasonic ultrasound gel
    Sono ultrasound wipes
    Sony UPP-110HG thermal printing paper
    Sony UPC-21L color thermal printing pack
    Mitsubishi CK30L printing paper
    Mitsubishi K95HG high gloss thermal printing paper

    GE Voluson i ports

    1 active transducer port
    2 USB Ports
    Ethernet LAN port
    1 PCMCIA Slot
    1 VGA Out Port
    1 proprietary Docking Port

    GE Voluson i Options

    These are features that are not standard on the GE Voluson i BT11, but which can be added to the system for an additional cost or when requested at purchase.

    3D/4D Expert
    4D View PC Software
    DICOM 3
    4D Biopsy
    VCI (Volume Contrast Imaging)
    XTD (Extended View)
    TUI (Tomographic Ultrasound Imaging)
    SonoVCAD heart
    SonoAVC follicle
    SonoVCAD labor
    STIC (Spatiotemporal Imaging Correlation)
    VOCAL II (Virtual Organ Computer-aided Analysis)
    Voluson Station
    Voluson Dock Cart with integrated power supply and three probe connectors
    GoPack carrying case
    USB Hub
    USB Stick
    DVD Drive
    External Hard Disk Drive
    Footswitch
    External Monitor Kit with Isolating Transformer
    Bluetooth Printer

    GE Voluson i optional technology definitions

    VCI: Volume Contrast Imaging on the Voluson-I utilizes 4D transducers to automatically scan multiple adjacent slices and delivers a real-time display of the ROI. This image results from a special rendering mode consisting of texture and transparency information. VCI improves the contrast resolution and therefore facilitates finding diffuse lesions.

    TUI: Tomographic Ultrasound Imaging is a new visualization mode for the Voluson-i in 3D and 4D data sets on the Voluson-i. The data is presented as slices through the data set which are parallel to each other. An overview image, which is orthogonal to the parallel slices, shows which parts of the volume are displayed in the parallel planes. This method of visualization is consistent with the way other medical systems such as CT or MRI, present the data to the user. The distance between the different planes can be adjusted to the requirements of the given data set. In addition it is possible to set the number of planes. The planes and the overview image can also be printed to a DICOM printer, for easier comparison of the ultrasound data with CT and/or MRI data.

    SonoVCAD Heart: A technology that automatically generates a number of views of the fetal heart to make diagnosis easier.

    SonoAVC follicle: A Voluson-i technology that automatically detects follicles in a volume of an organ (e.g., ovary) and analyzes their shape and volume. From the calculated volume an average diameter can be calculated. It also lists objects according to their size.

    SonoVCAD labor: Allows the Voluson-i user to measure fetal progression during the second stage of labor such as fetal head progression, rotation and direction. Visual evidence and objective data of the labor process are provided. All SonoVCAD labor measurements are automatically added to the worksheet

    STIC: Spatiotemporal Imaging Correlation is a fetal echo provided by the Voluson-i that visualizes the fetal heart or an artery in static 3D.

    VOCAL II: Virtual Organ Computer-aided Analysis is an imaging program on the Voluson-i for cancer diagnosis, therapy planning and follow-up therapy control. It offers contour detection of structures and volume calculation. A virtual shell can be set around the contour of the lesion. VOCAL automatically calculates the vascularization within the shell by 3D color histogram by comparing the number of color voxels to the number of grayscale voxels.

    GE Voluson i Standard Imaging Modes

    B-mode (2D)
    M-mode (M)
    M-Color-Mode (MC)
    Color Flow Mode (C)
    Power Doppler Imaging (PD)
    HD-Flow Imaging (HD-Flow)
    PW Doppler / Spectral Doppler Mode (PW)
    Extended View (XTD View)
    Speckle Reduction Imaging II (SRI II)
    CrossXBeam (CRI)
    Real-time Triplex Mode
    Split, quad screen
    Volume Mode (3D/4D) :
    3D Static
    3D with Color Flow
    4D Real-Time

    Voluson i Optional Imaging Modes

    Volume Contrast Imaging (VCI)
    Spatiotemporal Image Correlation (STIC)
    Tomographic Ultrasound Imaging (TUI)

    GE Voluson i Applications

    Applications or Apps are the types of exams or studies that an ultrasound machine can do. More than this if an ultrasound machine supports a specific application it will have calculations, measurement and reporting software included to support those apps and make them useful in a clinical environment.

    The GE Voluson i is able to do a variety of applications but it’s focus is women’s health and 4D.

    Obstetrics
    Fetal
    Gynecology
    Abdominal
    Fertility
    Small-Parts (Breast, Testes, Thyroid, etc.)
    Peripheral Vascular
    Musculoskeletal conventional and superficial
    Transvaginal
    Transrectal
    Pediatrics
    Urology
    Oncology
    Orthopedics
    Vascular
    Cardiac (fetal cardio)
    Neurology

    CLICK HERE TO REQUEST A PRICE QUOTE

    Year Launched 2006
    Estimated Market Price high
    Monitor 15″ TFT LCD
    Tilt/Rotate Adjustable Monitor No
    Monitor Resolution 1027*768
    Image Size Resolution 800*600
    Touch Screen No
    Trackball or Trackpad Trackball
    CP Back-Lighting Yes
    Weight 12.3lbs (5.6kg)
    Probe Ports 1
    Battery Yes
    Boot-Up Time
    Sleep Mode
    Maximum Depth of Field 30cm
    Minimum Depth of Field 0-2cm
    Cart Yes
    Independent Steer & Lockable Wheels Yes
    2D, M mode Yes
    M-color Flow Mode Yes
    Anatomical M-mode No
    Trapezoidal Mode Yes
    Color, Power Angio, Pulse Wave Doppler Yes
    Bi-directional Power Yes
    SCW Doppler No
    Tissue Doppler(Velocity) Imaging No
    Freehand 3D Yes
    Live 3/4D OB/GYN Yes
    HD Live No
    STIC Yes
    Live 3D Echo No
    Stress Echo No
    Strain and Strain Rate No
    B Flow No
    Panoramic Imaging No
    Contrast Imaging-Cardiac No
    Contrast Imaging – General Imaging No
    Strain-based Elastography No
    Shear Wave Elastography No
    Tissue Harmonic Imaging Yes
    Spatial Compounding(=CrossXbeam) Yes
    Speckle Reduction (=SRI) Yes
    Auto Image Opt(B mode) Yes
    Auto Image Opt(Doppler) Yes
    Write Zoom Yes
    Triplex Mode Yes
    Needle Enhancement or Needle Recognition No
    Auto NT Measurement Yes
    Auto Follicle 2D Measurement Yes
    Auto Follicle 3D Measurement Yes
    Auto IMT No
    Auto IMT (Real Time) No
    Automated B/M/D Measurement No
    Automated LH Measurement(Automated Function Imaging(AFI), Cardiac Motion Quantification(CMQ), or Auto EF(Ejection Fraction) No
    Live Dual (B/BC) Mode Yes
    SmartExam or Scan Assistant No
    Fusion No
    Raw Data File No
    Flexible Report No
    Barcode Reader No
    Gel Warmer No
    Abdominal Yes
    Women’s Health Care Yes
    OB Yes
    Fetal Echo No
    Vascular Yes
    TCD(Transcranial) No
    Small Parts Yes
    MSK/Anesthesiology Yes
    Pediatrics Yes
    Urology Yes
    Echocardiography_Adult Yes
    Interventional Cardiology No
    Echocardiography_Pediatric No
    Echocardiography_Neonate No
    Stress Echocardiography No
    Transesophageal Echo_Adult No
    Transesophageal Echo_Pediatric No
    Internal Medicine w/ Shared Service Yes
    Surgury No
    Interventional Radiology No
    Contrast Imaging_General Imaging No
    Contrast Imaging_Cardiac No
    Bowel Imaging Yes
    Strain Elastography No
    Shear Wave Elastography No
    Convex (1~6Mhz) Yes
    Convex (2~9Mhz) No
    Single Crystal Convex (1~6Mhz) No
    Single Crystal Convex (2~9Mhz) No
    Single Crystal Micro Convex No
    2D Arrary 3D Convex No
    Micro Convex (5~8Mhz) No
    Single Crystal Endocavity_Straight Type No
    Endocavity_Curved Type Yes
    BiPlane Endo Rectal No
    Biplane Micro Convex (3~10MHz)
    3D Convex Yes
    3D Convex Light Weight Yes
    3D Endocavity Yes
    3D Micro Convex Yes
    3D Linear Yes
    Linear (>14Mhz) Yes
    Linear (3~12Mhz) Yes
    Linear (<9Mhz) Yes
    Single Crystal Linear No
    Single Crystal Linear (3~12Mhz) No
    Single Crystal Linear (<9Mhz) No
    Linear 50mm No
    Linear 25mm No
    Hockey stick (<13Mhz) No
    Hockey stick (>13Mhz) No
    T or L shape Intra Operative No
    Laparoscopic No
    Phased Array_Adult No
    Single Crystal Phased Array_Adult No
    2D Arrary 3D Phased Array No
    Phased Array_Pediatric No
    Single Crystal Phased Array_Pediatric No
    Phased Array_Neonate No
    ICE No
    TEE_Adult No
    TEE_Pediatric No
    2D Array 3D TEE No
    Pencil CW (2Mhz) No
    Pencil CW (5 or 6Mhz) No
    DICOM 3.0 Yes(Option)
    DICOM SR_Cardiac No
    DICOM SR_Vascular No
    DICOM SR_OB/GYN Yes
    JPEG, WMV, & AVI Yes
    USB Yes(2)
    HDD/SDD 80GB
    DVD/CD RW Yes (External)
    Wireless LAN Yes

    CLICK HERE TO REQUEST A PRICE QUOTE

    Additional information

    Condition

    Refurbished

    Manufacture

    GE

    Request A Quote

    Name(Required)
    This field is for validation purposes and should be left unchanged.

    Product Enquiry

    Request A Quote

    Name(Required)
    This field is for validation purposes and should be left unchanged.

    Get In Touch

    Name(Required)
    This field is for validation purposes and should be left unchanged.

    Application For Financing

    Step 1 of 3

    Business Address
    Name Of Officer Signing Documents